Yueqing Leyu Electric Automation Co., Ltd.

home products TRIPLE output switching power supply switching power supply

switching power supply

Product Details:

Output Type Single
Place of Origin Zhejiang, China (Mainland)
Brand Name LEYU
Model Number T-60

Payment & Shipping Terms:

Supply Ability: 80000 Piece/Pieces per Month

Detailed Product Description


  switching power supply 
 
 
 

Model
Specification

T-60A

T-60B

T-60C

CH1

CH2

CH3

CH1

CH2

CH3

CH1

CH2

CH3

DC output voltage

5V

12V

-5V

5V

12V

-12V

5V

15V

-15V

Output voltage errorNote2

±2%

±6%

±6%

±2%

±6%

±6%

±2%

±6%

±6%

Rated output current

5A

2.5A

0.5A

5A

2.5A

0.5A

5A

2.5A

0.5A

Output current rage

0.5-7A

0.2-3.5A

0-0.1A

0.5-7A

0.2-3.5A

0-0.1A

0.5-7A

0.2-3.5A

0-0.1A

Wave and noise(Note 3

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

Inlet stability(Note 4

±0.5%

±1%

±0.5%

±0.5%

±1%

±0.5%

±0.5%

±1%

±0.5%

Load stablity (Note 5

±1%

±4%

±1%

±1%

±4%

±1%

±1%

±4%

±1%

DC output power

57.5W

61W

62.5W

Efficiency

72%

72%

72%

Adjustable range for DC voltage

CH1;+10,-5%

CH1:+10,-5%

CH1:+10,-5%

AC input voltage range

85-264VAC 47-63Hz120-370VDC

Input current

2A/115V 1A/230A

AC INnrush current

Cold-start current 30A/115V 60A/230V

Leakage current

<1mA/240VAC

Overload proctection

105%-150%Type:Foldback:current limiting reset:auto recovery

Over-voltage protection

CH1:5.75-6.75V

High-temperature protection

Temperature coefficient

±0.03%/0-50ON+5V

Setup rise hold up time

800ms,50ms,10ms/115VAC 300ms.50ms,80ms/230VAC

Vibration

10-500Hz,2G 10min,/1cycle,Period for60min,Each axes

Withstand voltage

Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC

Isolation resistance

Input and output internal:Input and enclosure,Output and enclosure500VDC/100MΩ

Working temperature and humidity

-10~+60Refer to output derating curve,20%~90%RH

Store temperature and humidity

-20~+85.10%~95%RH

Overall dimension

159×97×38mm

Weight

0.56Kgs

Safety standards

UL 1012 TUV EN60950(IEC950,UL1950)

EMC standards

CISPR22(EN55022),class B,IEC801-2,-3,-4,IEC555-2 Verification

Note
1.The testing condition for the paramenter above is :230VAC input,rated load,2570% RH.Humidity.
2.Error.include the setting error,line stability and load stability.(Note:5).
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.
5.Load stability test:the load is from 0% to 100%.
6.Total output canbe maximum Current,total load can not exceed the maximum output power.
7.C23must be knocked down.

switching power supply switching power supply

Send your message to this supplier
« Prev Product ... 8 9 10 11 12 13 14 Next Product »

Other Products from this Supplier

Company Info

Yueqing Leyu Electric Automation Co., Ltd.
[China (Mainland)]
[Verified Member]

City: Wenzhou
Province/State: Zhejiang
Country/Region : China (Mainland)

Business Type:Manufacturer, Trading Company, Buying Office

View Contact Details

Email this page Bookmark this page Print this Page