Yueqing Leyu Electric Automation Co., Ltd.

home products DUAL output switching power supply switching power supply

switching power supply

Product Details:

Output Type Single
Place of Origin Zhejiang, China (Mainland)
Brand Name LEYU
Model Number D-60

Payment & Shipping Terms:

Supply Ability: 80000 Piece/Pieces per Month

Detailed Product Description


  switching power supply 
 

Model
Specification

D-60A

D-60B

CH1

CH2

CH1

CH2

DC output voltage

5V

12V

5V

24V

Output voltage errorNote2

±2%

±6%

±2%

±5%

Rated output current

4A

3A

3A

1.8A

Output current rage

0.3-6A

0.2-4A

0.3-6A

0.2-2.2A

Wave and noise(Note 3

75mVp-p

150mVp-p

75mVp-p

150mVp-p

Inlet stability(Note 4

±0.5%

±1%

±0.5%

±0.5%

Load stablity (Note 5

±0.5%

±4%

±0.5%

±4%

DC output power

56W

58W

Efficiency

73%

73%

Adjustable range for DC voltage

CH1;+10,-5%

CH1:+10,-5%

AC input voltage range

85-264VAC 47-63Hz,120-370VDC

Input current

2A/115V 1A/230A

AC INnrush current

Cold-start current30A/115V 60A/230V

Leakage current

<1mA/240VAC

Overload proctection

105%-150%Type:Foldback:current limiting reset:auto recovery

Over-voltage protection

CH15.75~6.75V

High-temperature protection

Temperature coefficient

±0.03%/0-50ON+5V

Setup rise hold up time

800ms,50ms,30ms/115AC 300ms,50ms,80ms/230AC

Vibration

10-500Hz,2G 10min,/1cycle,Period for60min,Each axes

Withstand voltage

Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC

Isolation resistance

Input and output internal:Input and enclosure,Output and enclosure500VDC/100MΩ

Working temperature and humidity

-10~+60Refer to output derating curve,20%~90%RH

Store temperature and humidity

-20~+85.10%~95%RH

Overall dimension

159×97×38mm

Weight

0.55Kgs

Safety standards

UL 1012 TUV EN60950(IEC950,UL1950)Approved

EMC standards

CISPR22EN55022class B,IEC801-2,3,4,IEC555-2 Approved

Note
1.The testing condition for the paramenter above is :230VAC input,rated load,2570% RH.Humidity.
2.Error.include the setting error,line stability and load stability.(Note:5).
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.
5.Load stability test:the load is from 0% to 100%.
6.Total output canbe maximum Current,total load can not exceed the maximum output power
7C236 must be knocked down.

switching power supply switching power supply

Send your message to this supplier
« Prev Product ... 36 37 38 39 40 41 42 ... Next Product »

Other Products from this Supplier

Company Info

Yueqing Leyu Electric Automation Co., Ltd.
[China (Mainland)]
[Verified Member]

City: Wenzhou
Province/State: Zhejiang
Country/Region : China (Mainland)

Business Type:Manufacturer, Trading Company, Buying Office

View Contact Details

Email this page Bookmark this page Print this Page