switching power supply
Product Details:
| Output Type | Single |
|---|---|
| Place of Origin | Zhejiang, China (Mainland) |
| Brand Name | LEYU |
| Model Number | Q-120 |
Payment & Shipping Terms:
| Price: | FOB Ningbo USD 15~20 |
|---|---|
| Packaging Details: | Paper box |
| Delivery Time: | Two week |
| Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
| Supply Ability: | 20000 Piece/Pieces per Month |
Detailed Product Description
| Model | Q-120B | Q-120C | Q-120D | |||||||||
| Specification | CH1 | CH2 | CH3 | CH4 | CH1 | CH2 | CH3 | CH4 | CH1 | CH2 | CH3 | CH4 |
| DC output voltage | 5V | 12V | -5V | -12V | 5V | 15V | -5V | 15V | 5V | 12V | 24V | -12V |
| Output voltage errorNote2 | ±2% | ±6% | ±6% | ±6% | ±2% | +10,-5% | ±6% | +10,-5% | ±2% | ±6% | ±6% | ±6% |
| Rated output current | 11A | 4A | 1A | 1A | 10A | 3.5A | 1A | 1A | 8A | 2A | 2A | 1A |
| Output current rage | 2-12A | 0.5-5A | 0.2-1A | 0.2-1A | 2-12A | 0.5-5A | 0.2-1A | 0.2-1A | 2-12A | 0.2-5A | 0.2-2A | 0.2-1A |
| Wave and noise(Note 3 | 80mV | 120mV | 80mV | 120mV | 80mV | 150mV | 80mV | 150mV | 80mV | 120mV | 80mV | 120mV |
| Inlet stability(Note 4 | ±0.5% | ±1% | ±1% | ±1% | ±0.5% | ±1% | ±1% | ±1% | ±0.5% | ±1% | ±1% | ±1% |
| Load stablity (Note 5 | ±1% | ±5% | ±5% | ±5% | ±0.5% | ±7% | ±8% | ±8% | ±0.5% | ±7% | ±8% | ±8% |
| DC output power | 120W | 122.5W | 124W | |||||||||
| Efficiency | 77% | 76% | 80% | |||||||||
| Adjustable range for DC voltage | CH1;+10,-5% | CH1;+10,-5% | CH1;+10,-5% | |||||||||
| AC input voltage range | 88-132VAC/176-264VAC 47-63Hz,240-370VDC | |||||||||||
| Input current | 2.5A/115V 1.25A/230A | |||||||||||
| AC INnrush current | Cold-start current 35A | |||||||||||
| Leakage current | <3.5mA/240VAC | |||||||||||
| Overload proctection | 105%-150%Type:Foldback:current limiting reset:auto recovery | |||||||||||
| Over-voltage protection | CH15.75~6.75V | |||||||||||
| High-temperature protection | ||||||||||||
| Temperature coefficient | ±0.03% | |||||||||||
| Setup rise hold up time | 200ms,50ms,20ms | |||||||||||
| Vibration | 10-500Hz,2G 10min,/1cycle,Period for60min,Each axes | |||||||||||
| Withstand voltage | Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC | |||||||||||
| Isolation resistance | Input and output internal:Input and enclosure,Output and enclosure500VDC/100MΩ | |||||||||||
| Working temperature and humidity | -10~+60Refer to output derating curve,20%~90%RH | |||||||||||
| Store temperature and humidity | -20~+85.10%~95%RH | |||||||||||
| Overall dimension | 199×110×50mm | |||||||||||
| Weight | 0.88Kgs | |||||||||||
| Safety standards | UL 1950 TUV EN 60950 Approved | |||||||||||
| EMC standards | CISPR22(EN55022)class B,IEC8011-2,3,4,IEC555-2 Approved | |||||||||||
| Note | ||||||||||||
| 1.The testing condition for the paramenter above is :230VAC input,rated load,2570% RH.Humidity. | ||||||||||||
| 2.Error.include the setting error,line stability and load stability.(Note:5). | ||||||||||||
| 3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. | ||||||||||||
| 4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. | ||||||||||||
| 5.Load stability test:the load is from 0% to 100%. | ||||||||||||
| 6.Total output canbe maximum Current,total load can not exceed the maximum output power | ||||||||||||
| 7C2311 must be knocked down. | ||||||||||||
switching power supply
Other Products from this Supplier
See more
CE power supply, single output switching power supply, switch power supplies products from this supplier.
Company Info
Yueqing Leyu Electric Automation Co., Ltd.
[China (Mainland)]
[Verified Member]
City: Wenzhou
Province/State: Zhejiang
Country/Region : China (Mainland)
Business Type:Manufacturer, Trading Company, Buying Office
Online Postings: Products