Detailed Product Description


 

Model
Specification

T-50A

T-50B

T-50C

T-50D

CH1

CH2

CH3

CH1

CH2

CH3

CH1

CH2

CH3

CH1

CH2

CH3

DC output voltage

5V

12V

-5V

5V

12V

-12V

5V

15V

-15V

5V

12V

24V

Output voltage errorNote2

±2%

±5%

±5%

±2%

±5%

±5%

±2%

±5%

±5%

±2%

±6%

±6%

Rated output current

3A

2A

0.5A

3A

2A

0.5A

3A

1.5A

0.5A

3A

1.5A

0.5A

Output current rage

0.6-7A

0.2-1A

0.2-1A

0.6-5A

0.2-1A

0.2-1A

0.6-4A

0.2-1A

0.2-1A

0.6-4A

0.2-1.2A

0.2-1.2A

Wave and noise(Note 3

100mV

100mV

100mV

100mV

100mV

100mV

100mV

100mV

100mV

100mV

100mV

100mV

Inlet stability(Note 4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±1%

Load stablity (Note 5

±1%

±4%

±4%

±1%

±4%

±4%

±1%

±4%

±4%

±1%

±5%

±5%

DC output power

52W

49W

50W

51W

Efficiency

66%

69%

71%

72%

Adjustable range for DC voltage

CH1;+10,-5%

CH1:+10,-5%

CH1:+10,-5%

CH1:+10,-5%

AC input voltage range

85-132VAC/170-264VAC 47-63Hz,240-370VDC

Input current

1.6A/115V 0.8A/230A

AC INnrush current

Cold-start current 20A/115V 40A/230V

Leakage current

<0.5mA/240VAC

Overload proctection

105%-150%Type:Foldback:current limiting reset:auto recovery

Temperature coefficient

±0.03%/0-50ON+5V

Setup rise hold up time

200ms,50ms,16ms

Vibration

10-500Hz,2G 10min,/1cycle,Period for60min,Each axes

Withstand voltage

Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC

Isolation resistance

Input and output internal:Input and enclosure,Output and enclosure500VDC/100MΩ

Working temperature and humidity

-10~+60Refer to output derating curve,20%~90%RH

Store temperature and humidity

-20~+85,10%~95%RH

Overall dimension

195×97×38mm

Weight

0.54Kgs

Safety standards

Meet UL 1012 requirement(Not apply for the mark)

Note
1.The testing condition for the paramenter above is :230VAC input,rated load,2570% RH.Humidity.
2.Error.include the setting error,line stability and load stability.(Note:5).
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.
5.Load stability test:the load is from 0% to 100%.
6.Total output canbe maximum Current,total load can not exceed the maximum output power

switching power supply switching power supply

Send your message to this supplier
« Prev Product ... 8 9 10 11 12 13 14 Next Product »

Other Products from this Supplier

Company Info

Yueqing Leyu Electric Automation Co., Ltd.
[China]
[Verified Member]

Business Type:Manufacturer, Trading Company, Buying Office

City: WENZHOU
Province/State: Zhejiang
Country/Region : China

View Contact Details

Email this page Bookmark this page Print this Page