switching power supply
Product Details:
| Output Type | Single |
|---|---|
| Place of Origin | Zhejiang, China |
| Brand Name | LEYU |
| Model Number | D-120 |
Payment & Shipping Terms:
| Supply Ability: | 80000 Piece/Pieces per Month |
|---|
Detailed Product Description
| Model Specification | D-120A | D-120B | ||
CH1 | CH2 | CH1 | CH2 | |
| DC output voltage | 5V | 12V | 5V | 24V |
| Output voltage errorNote2 | ±2% | ±6% | ±2% | ±7% |
| Rated output current | 12A | 5A | 6A | 4A |
| Output current rage | 2-12A | 0.5-5A | 2-10A | 0.4-4A |
| Wave and noise(Note 3 | 60mVp-p | 120mVp-p | 60mVp-p | 150mVp-p |
| Inlet stability(Note 4 | ±0.5% | ±1% | ±0.5% | ±1% |
| Load stablity (Note 5 | ±0.5% | ±5% | ±0.5% | ±6% |
| DC output power | 120W | 126W | ||
| Efficiency | 78% | 80% | ||
| Adjustable range for DC voltage | CH1;+10,-5% | CH1:+10,-5% | ||
| AC input voltage range | 88-132VAC/176-264VAC 47-63Hz,248-370VDC | |||
| Input current | 2.5A/115V 1.25A/230A | |||
| AC INnrush current | Cold-start current 35A | |||
| Leakage current | <3.5mA/240VAC | |||
| Overload proctection | 105%-150%Type:Foldback:current limiting reset:auto recovery | |||
| Over-voltage protection | CH15.75~6.75V | |||
| High-temperature protection | ||||
| Temperature coefficient | ±0.03%/0-50ON+5V | |||
| Setup rise hold up time | 200ms,50ms,20ms | |||
| Vibration | 10-500Hz,2G 10min,/1cycle,Period for60min,Each axes | |||
| Withstand voltage | Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC | |||
| Isolation resistance | Input and output internal:Input and enclosure,Output and enclosure500VDC/100MΩ | |||
| Working temperature and humidity | -10~+60Refer to output derating curve,20%~90%RH | |||
| Store temperature and humidity | -20~+85.10%~95%RH | |||
| Overall dimension | 199×110×50mm | |||
| Weight | 0.85Kgs | |||
| Safety standards | UL1950 TUVEN60950 | |||
| EMC standards | CISPR22EN55022class B,IEC801-2,3,4,IEC555-2 Approved | |||
| Note 1.The testing condition for the paramenter above is :230VAC input,rated load,2570% RH.Humidity. 2.Error.include the setting error,line stability and load stability.(Note:5). 3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. 4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. 5.Load stability test:the load is from 0% to 100%. 6.Total output canbe maximum Current,total load can not exceed the maximum output power 7C236 must be knocked down. | ||||
switching power supply
Other Products from this Supplier
See more
CE switching power supply, power supply, single switching power supply products from this supplier.