Detailed Product Description


switching power supply

S-201-5S-201-7.5S-201-12S-201-13.5S-201-15S-201-24S-201-27S-201-48
Model
Specification
DC output voltage
3V
7.5V
12V
13.5V
15V
24V
27V
48V
Output voltage errorNote2
±2%
±2%
±1%
±1%
±1%
±1%
±1%
±1%
Rated output current
40A
26.5A
16.5A
14.7A
13A
8.3A
7.4A
4.2A
Output current rage
0-40A
0-26.5A
0-16.5A
0-14.7A
0-13A
0-8.3A
0-7.4A
0-4.2A
Wave and noise(Note 3
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
240mVp-p
Inlet stability(Note 4
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
Load stablity (Note 5
±1%
±1%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
DC output power
200W
198.75W
198W
198.45W
198W
199.2W
199.8W
201.6W
Efficiency
74%
79%
80%
80%
81%
83%
83%
84%
Adjustable range for DC voltage
4.5-5.6V
6-9V
10-13.2V
12-15V
13.5-18V
20-26.4V
26-32V
41-56V
AC input voltage range 90~132VAC/180-264VAC selected by switch 47-63Hz254-370VDC
Input current3.6A/115V 1.8A/230V
AC INnrush current

25A/115V 50A/230V

Leakage current <3.5mA/240VAC
Overload proctection 105%~150% Tpye:pulsing hiccp shutdown Reset:auto recovery
Over-voltage protection 5.75~6.75V9.4~10.9V13.8~16.2V15.5~18.2V18~21V27.6~32.4V33.7~39.2V57.6~67.2V
High-temperature protection ERH3≥90 Output shutdown
Temperature coefficient ±0.03%/(0~50%)
Setup rise hold up time 200ms,100ms,20ms
Vibration10~500Hz,2G 10min,/1cycle,Period for 60min,each axes
Withstand voltage Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC
Isolation resistanceInput and output internal:Input and enclosure,Output and enclosure500VDC/100MΩ
Working temperature and humidity -10~+60Refer to output derating curve,20%~90%RH
Store temperature and humidity -20~+85,10%~95%RH
Overall dimension215×115×50mm
Weight0.9Kgs
Safety standards Design refer to UL1950
EMC standards Design refer FCC PART15 J Conduction class A
Note
1.The testing condition for the paramenter above is :230VAC input,rated load,2570% RH.Humidity.
2.Error.include the setting error,line stability and load stability.(Note:5).
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.
5.Load stability test:the load is from 0% to 100%.
6.C236 must be knocked down.

switching power supply switching power supply

Send your message to this supplier
« Prev Product 1 2 3 4 5 6 7 ... Next Product »

Other Products from this Supplier

Company Info

Yueqing Leyu Electric Automation Co., Ltd.
[China]
[Verified Member]

Business Type:Manufacturer, Trading Company, Buying Office

City: WENZHOU
Province/State: Zhejiang
Country/Region : China

View Contact Details

Email this page Bookmark this page Print this Page