switching power supply
Product Details:
| Output Type | Single |
|---|---|
| Place of Origin | Zhejiang, China |
| Brand Name | LEYU |
| Model Number | S-145-12 |
Payment & Shipping Terms:
| Supply Ability: | 80000 Piece/Pieces per Month |
|---|
Detailed Product Description
| Specification | S-145-5 | S-145-7.5 | S-145-12 | S-145-24 |
| DC output voltage | 5V | 7.5V | 12V | 24V |
| Output voltage errorNote2 | ±2% | ±1% | ±1% | ±1% |
| Rated output current | 25A | 18A | 12A | 24A |
| Output current rage | 0-25A(Biggest30A | 0-18A(Biggest21A | 0-12A(Biggest14A | 0-24A(Biggest7A |
| Wave and noise(Note 3 | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
| Inlet stability(Note 4 | ±0.5% | ±0.5% | ±0.5% | ±0.3% |
| Load stablity (Note 5 | ±0.5% | ±0.5% | ±0.5% | ±0.3% |
| DC output power | 125W | 135W | 144W | 144W |
| Efficiency | 78% | 80.50% | 80.50% | 83.50% |
| Adjustable range for DC voltage | 4.75-5.5V | 6-8V | 10.8-13.2V | 21-28V |
| AC input voltage range | 85-132VAC/170-264VACSelected by switch47-63Hz240-370VDC | |||
| Input current | 0.5A/115V 0.25A/230A | |||
| AC INnrush current | Cold-start current15A/115V 30A/230V | |||
| Leakage current | <0.5mA/240VAC | |||
| Overload proctection | 105%-150%Type:Foldback:current limiting reset:auto recovery | |||
| High-temperature protection | ||||
| Temperature coefficient | ±0.03%/0-50 | |||
| Setup rise hold up time | 100ms,50ms,20ms | |||
| Vibration | 10-500HZ,2G 10min,/1cycle,Period for60min,Each axes | |||
| Withstand voltage | Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC | |||
| Isolation resistance | Input and output internal:Input and enclosure,Output and enclosure500VDC/100MΩ | |||
| Working temperature and humidity | -10~+60Refer to output derating curve,20%~90%RH | |||
| Store temperature and humidity | -20~+85,10%~95%RH | |||
| Overall dimension | 199×98×38mm | |||
| Weight | 0.7Kgs | |||
| Safety standards | Meet UL 1012 requirement(Not apply for the mark) | |||
| EMC standards | Meet FCC part15J Conduction classB | |||
| Note | ||||
| 1.The testing condition for the paramenter above is :230VAC input,rated load,2570% RH.Humidity. | ||||
| 2.Error.include the setting error,line stability and load stability.(Note:5). | ||||
| 3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. | ||||
| 4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. | ||||
| 5.Load stability test:the load is from 0% to 100%. | ||||
switching power supply
Other Products from this Supplier
See more
switch power, switch power supplies, single switching power supply products from this supplier.
Product Showcase[30]
Company Info
Yueqing Leyu Electric Automation Co., Ltd.
[China]
[Verified Member]
Online Postings: Products, Selling Leads
Business Type:Manufacturer, Trading Company, Buying Office
City: WENZHOU
Province/State: Zhejiang
Country/Region : China